Figure 8. ABR analysis and EP measurement in KI mice after noise exposure. (A) ABR audiograms tracking changes of thresholds after one episode of a two-hour, 100 dB SPL, 8-16 kHz band-pass noise exposure. ABR thresholds of both groups recovered to the baseline level at 15 days after noise exposure (P>0.05 for both genotypes, two-way ANOVA followed by Bonferroni post-test). (B) EPs didn’t change in both wild-type and homozygous mice at day 15 of noise exposure (P>0.05, Student’s unpaired t-test with Welch’s correction). Baseline EPs were obtained by pooling data from young individuals less than 20 weeks old in